DS478 - Safety of Nuclear Fuel Cycle Facilities

Status: SSR-4

Veröffentlichung  2017

Revision von NS-R-5 Rev.1  (Ex DS439)

Beteiligte IAEO-Komitees: NUSSC, RASSC, TRANSSC, WASSC, EPReSC

Specific Safety Requirements

STEP 12 Kommentare der SSCs  
STEP 11 Kommentare der SSCs und IAEO-Bewertung IAEO-Zusammenfassung nach STEP 11
STEP 8 Kommentare der Mitgliedsstaaten
und IAEO-Bewertung
IAEO-Zusammenfassung nach STEP 8
STEP 7 Kommentare der SSCs und IAEO-Bewertung IAEO-Zusammenfassung nach STEP 7
STEP 4    
STEP 3 Kommentare der SSCs und IAEO-Bewertung IAEO-Zusammenfassung nach STEP 3

Document Preparation Profile "DPP"

Zurück zu „IAEO Safety Standards Series“ (Übersicht aller derzeit gültigen Sicherheitsstandards)

Background Information

The document (NS-R-5) was first published in 2008, the scope remains essentially unchanged.

The current revision (DS 478) was initiated to

  • comply with the long term structure of safety standards approved in 2008
  • ensure coherency and consistency with the other relevant IAEA Safety Standards (e.g. SF-1 and GSRs), and the recently published NPPs documents (SSR-2/1 and SSR-2/2)
  • incorporate experience on application of the documents, and the operating experience feedback from the IAEA Incident reporting systems, and the feedback from the accident at the FukushimaDaiichi NPP
     

The new information in DS478 includes

  • Relevant lessons from the accident at Fukushima Daiichi; Design Extension Conditions, improved regulatory effectiveness, severe accident management, Periodic Safety Review, robust cooling, greater strength / independence at DiD levels 3 and 4, hydrogen control.
  • Sections “preparation for decommissioning” to replace “decommissioning”, as requested by the safety committees
  • Interface between safety and security
     

Other Changes

  • Consistency of “regulatory supervision”, “siting”, “management system” with other revised standards in accordance with committee requests
  • Stronger requirements for ageing management and on-site material transfers
  • Material more suitable to guidance removed
  • References updated